Background: The combined spinal-epidural (CSE) technique offers the rapid onset of spinal anaesthesia with the flexibility of epidural top-ups and postoperative analgesia. The conventional dual-space CSE, though anatomically appealing, carries a theoretical risk of catheter shearing when a lumbar epidural catheter is inadvertently transfixed by a subsequently introduced spinal needle at a higher interspace. We describe a modified thoraco-lumbar double-space CSE that resequences the workflow to structurally eliminate this risk. Methods: In this prospective observational study, 45 ASA I–II women scheduled for elective total abdominal hysterectomy (TAH) underwent CSE using the "Spinal-First, Injection-Last" technique. A 25G Quincke spinal needle was introduced at T11–T12 and secured after CSF confirmation, without injection. An 18G Tuohy needle was then used to identify the epidural space between L1–L3, and a catheter was threaded 4–5 cm cephalad, injection 12.5 mg of 0.5% hyperbaric bupivacaine with 25 μg fentanyl injected through the pre-placed thoracic spinal needle followed by fixation of epidural catheter . Block characteristics, haemodynamics, complications and postoperative analgesia were recorded. Results: The technique was successful in all 45 patients (100%). Median time to sensory block at T6 was 4 (3–6) minutes and to Bromage 3 motor block was 5 (4–7) minutes. Peak sensory level was T6 (T5–T7). No catheter shearing, post-dural puncture headache or neurological deficit was recorded. Hypotension requiring vasopressor occurred in 12 (26.7%) patients. Mean duration of surgical anaesthesia was 182 ± 21 minutes; postoperative epidural analgesia produced a mean VAS at rest of 2.1 ± 0.8 at 24 hours. Conclusion: The "Spinal-First, Injection-Last" thoraco-lumbar CSE technique is a safe, reproducible modification that structurally eliminates catheter shearing risk while delivering the dense surgical block and prolonged analgesia required for TAH.
Total abdominal hysterectomy (TAH) remains one of the most frequently performed major gynaecological surgeries worldwide and imposes significant somatic, visceral and postoperative analgesic demands on the anaesthetic technique.¹,² While general anaesthesia (GA) with endotracheal intubation is a traditional choice, neuraxial techniques offer well-documented benefits including reduced blood loss, attenuated surgical stress response, decreased opioid requirement, earlier return of bowel function, and a lower incidence of postoperative nausea and vomiting.³⁻⁵
Single-shot spinal anaesthesia provides a rapid, dense and reliable block but is limited by a finite duration that is often inadequate for hysterectomies, particularly when adhesions, endometriosis or malignancy prolong operative time.⁶ Continuous epidural anaesthesia offers titratable, prolonged analgesia but is limited by slow onset, patchy block, and higher failure rates when used as the sole surgical anaesthetic.⁷,⁸ The combined spinal-epidural (CSE) technique was developed to marry the reliability of spinal anaesthesia with the flexibility of epidural top-ups and postoperative analgesia.⁹⁻¹¹
Two principal approaches to CSE are described: the single-space needle-through-needle (NTN) technique and the dual-space (or double-space) technique.¹²,¹³ In the NTN method, a Tuohy needle is first placed in the epidural space and a longer spinal needle is passed coaxially through it to breach the dura. Although widely adopted, NTN is associated with failed dural puncture despite correct epidural placement, metallic particle generation, epidural catheter migration through the dural rent, and the inability to test the epidural catheter before spinal drug injection.¹⁴⁻¹⁷. The dual-space technique addresses several of these concerns by allowing independent placement and testing of the epidural catheter and the spinal block at separate interspaces.¹⁸ However, when the conventional sequence is followed—first the epidural catheter at a lower interspace, then the spinal at a higher interspace—the advancing spinal needle can inadvertently transfix the previously placed catheter ("through-and-through" needle laceration), with catheter shearing on withdrawal.¹⁹⁻²¹ Multiple case reports describe retained catheter fragments requiring surgical retrieval following such injuries.²²,²³
For pelvic surgery such as TAH performed through a Pfannenstiel incision, the segmental innervation to be blocked comprises a well-defined territory: uterine visceral and somatic afferents ascend via T10–L1, with sympathetic fibres travelling through the uterine, pelvic and inferior/superior hypogastric plexuses into the lumbar splanchnic nerves; the parietal peritoneum of the pelvis draws its somatic supply from T11–L1; and the anterior abdominal wall — the rectus abdominis, pyramidalis, and the external oblique, internal oblique and transverse abdominis muscles — is innervated segmentally from T7–L1, with the skin over the Pfannenstiel incision supplied by the iliohypogastric and ilioinguinal nerves (T12–L1).²⁴,²⁵ A spinal block placed at T11–T12 therefore covers this entire territory in a single injection: the rectus and lateral abdominal wall muscles become flaccid, retraction of the Pfannenstiel wound is effortless for the operating surgeon, and uterine traction pain — with its associated vagally-mediated bradycardia and nausea — is abolished, yielding a quiet, well-relaxed surgical field. A lumbar spinal block, however dense, often produces an insufficiently high level for peritoneal traction pain, whereas a lumbar epidural alone is slow and unreliable for surgical anaesthesia. Low-thoracic spinal anaesthesia has therefore emerged as a safe and effective alternative, producing rapid, high-quality abdominal wall relaxation at reduced local anaesthetic doses.²⁶⁻²⁸
We hypothesised that a modified thoraco-lumbar double-space CSE, in which the spinal needle is placed and parked at T11–T12 first, the lumbar epidural catheter is threaded next between L1–L3, and the spinal anaesthetic is injected last through the pre-placed thoracic needle, would (a) structurally eliminate the possibility of the spinal needle transfixing the epidural catheter, (b) permit unhurried epidural catheter placement without racing against a rising sensory block, and (c) provide dense low-thoracic surgical anaesthesia with an intact lumbar epidural for postoperative analgesia. We present the technique, its rationale, and our initial clinical experience.
Study design and setting
This prospective observational study was conducted in the Department of Anaesthesiology, Mamata Academy of Medical Sciences, Bachupally, Hyderabad, over a period of 12 months (January 2025 – January 2026), after obtaining approval from the Institutional Ethics Committee (IEC No: MAMS/2024/AN/17) and written informed consent from all participants. The study conformed to the Declaration of Helsinki and was prospectively registered with the Clinical Trials Registry–India.²⁹
Participants
Consecutive adult women, aged 30–65 years, of American Society of Anesthesiologists (ASA) physical status I or II, scheduled for elective TAH under regional anaesthesia were enrolled. Exclusion criteria were: patient refusal, coagulopathy or ongoing anticoagulant therapy, local infection at the puncture site, known allergy to local anaesthetics, pre-existing neurological deficit, severe cardiovascular disease, gross spinal deformity, and body mass index (BMI) > 35 kg/m². A sample size of 45 was chosen based on a pilot audit of expected block characteristics using a precision-based approach with α = 0.05 and an anticipated 90% success rate.³⁰
Preoperative preparation
All patients underwent standard preoperative evaluation including complete blood count, coagulation profile, renal and hepatic function tests, electrocardiography and chest radiography where indicated. Patients were fasted for 8 hours for solids and 2 hours for clear fluids per institutional protocol. Oral pantoprazole 40 mg and alprazolam 0.25 mg were administered on the night before surgery.³¹
Intraoperative management
In the operating room, standard monitoring including 5-lead electrocardiography, non-invasive blood pressure at 3-minute intervals, and pulse oximetry was established. An 18G intravenous cannula was secured and co-loading with 10 mL/kg of Ringer's lactate solution was commenced.³²
The "Spinal-First, Injection-Last" technique
With the patient in the sitting position, the T11–T12 and L1–L2/L2–L3 interspaces were identified using surface landmarks (the T7 inferior scapular angle and Tuffier's line) and confirmed by counting.³³ The back was prepared with 2% chlorhexidine in 70% alcohol and draped aseptically.
Step 1 — Spinal First (dural puncture only): Local infiltration with 2 mL of 2% lignocaine was performed at T11–T12. A 25G Quincke spinal needle was introduced via a paramedian/midline approach with a slight cephalad angulation. On free flow of clear cerebrospinal fluid (CSF), the stylet was immediately reinserted; injection of the local anaesthetic was deliberately deferred. The hub of the needle was stabilised between the operator's non-dominant thumb and index finger, keeping the shaft strictly stationary.
Step 2 — Epidural Next (catheter placement): Without disturbing the spinal needle, the L1–L2 or L2–L3 interspace was infiltrated, and an 18G Tuohy needle was advanced through a midline or paramedian approach. The epidural space was identified using the loss-of-resistance-to-air technique, and a 20G multi-orifice catheter was threaded 4–5 cm into the epidural space in a cephalad direction.³⁴ The Tuohy needle was withdrawn over the catheter, and a test dose of 3 mL of 2% lignocaine with adrenaline 1:200 000 was administered to exclude intravascular or intrathecal placement.³⁵
Step 3 — Injection Last (spinal drug delivery): The stylet of the pre-placed thoracic spinal needle was removed, free CSF flow was reconfirmed, and 2.5 mL of 0.5% hyperbaric bupivacaine (12.5 mg) with 25 μg fentanyl (total volume 3 mL) was injected slowly over 15 seconds.³⁶
Step 4 — Catheter Safe (fixation): The spinal needle was withdrawn, and the epidural catheter was fixed with a transparent adhesive dressing. The patient was immediately positioned supine.
Because the spinal needle was static during epidural catheter placement, and because the T11–T12 spinal puncture site was cephalad to the L1–L3 catheter trajectory, there was no opportunity for the sharp bevel of the spinal needle to contact or transfix the catheter—the key mechanical advantage of this resequenced workflow.
Block assessment and intraoperative care
Sensory block was assessed by loss of pinprick sensation every 1 minute for the first 10 minutes, then every 5 minutes until fixation. Motor block was graded on the modified Bromage scale.³⁷ The following variables were recorded: time from spinal injection to onset of sensory block at T10, time to peak sensory level, time to Bromage 3 motor block, and duration of surgical anaesthesia (time from spinal injection to first request for epidural top-up or onset of pain during surgery). Hypotension (systolic BP < 90 mm Hg or a > 20% decrease from baseline) was treated with incremental intravenous ephedrine boluses of 6–12 mg (prepared by diluting a 30 mg ampoule to 5 mL, giving 6 mg/mL) together with rapid fluid loading; in our practice, phenylephrine is not routinely used for spinal-induced hypotension in this setting. Bradycardia (heart rate < 50 beats/min) was treated with intravenous atropine 0.6 mg. Epidural top-ups with 3–5 mL of 0.5% bupivacaine were administered if the sensory level regressed or the patient reported discomfort during surgery.
Postoperative analgesia
Epidural analgesia with 0.125% bupivacaine plus fentanyl 2 μg/mL at the rate of 4ml/hr was initiated at a background infusion with syringe pump.³⁸ Pain was assessed on a 0–10 visual analogue scale (VAS) at 2, 6, 12, 24 and 48 hours postoperatively. Rescue analgesia (intravenous tramadol 50 mg) was provided if VAS > 4.
Outcome measures
Primary outcomes were procedural success (defined as adequate surgical anaesthesia without conversion to GA) and epidural catheter integrity on removal. Secondary outcomes included block characteristics, intraoperative haemodynamic stability, postoperative pain scores, and complications (post-dural puncture headache, transient neurological symptoms, urinary retention, backache, and catheter-related complications).
Statistical analysis
Data were analysed using SPSS version 26.0 (IBM Corp, Armonk, NY, USA). Continuous variables were presented as mean ± standard deviation or median (interquartile range) as appropriate; categorical variables as counts and percentages. Normality was assessed with the Shapiro–Wilk test. A p-value < 0.05 was considered statistically significant.
Haemodynamic profile
Haemodynamic changes during the intraoperative period are shown in Figure 4. A modest decrease in systolic and mean arterial pressure was observed at 5–15 minutes post-injection, returning close to baseline by 30 minutes. Twelve patients (26.7%) developed hypotension requiring ephedrine (mean total dose 18 ± 6 mg, typically three boluses of 6 mg). Bradycardia occurred in 4 (8.9%) patients, all of whom responded to a single dose of atropine.
Complications and adverse events
No serious complications were observed. There were no cases of high spinal block, post-dural puncture headache, transient neurological symptoms, epidural haematoma, or catheter breakage. Minor complications are summarised in Table 3.
Table 3. Complications and adverse events (n = 45)
|
Event |
n (%) |
|
Hypotension (requiring vasopressor) |
12 (26.7) |
|
Bradycardia (requiring atropine) |
4 (8.9) |
|
Nausea / vomiting |
5 (11.1) |
|
Shivering |
6 (13.3) |
|
Urinary retention (>6 h) |
3 (6.7) |
|
Post-dural puncture headache |
0 (0) |
|
Transient neurological symptoms |
0 (0) |
|
Backache at 48 h |
2 (4.4) |
|
Catheter shearing / fragmentation |
0 (0) |
|
Failed technique / GA conversion |
0 (0) |
Postoperative analgesia
Postoperative pain scores were low and remained well controlled throughout the 48-hour observation period (Figure 5). Mean VAS at rest at 24 hours was 2.1 ± 0.8, and mean VAS on movement at the same time point was 3.1 ± 0.9. Only 4 patients (8.9%) required rescue tramadol during the first 24 hours. Ambulation was achieved in 40 patients (88.9%) by the end of postoperative day 1, and 43 (95.6%) by the end of day 2.
Our prospective series of 45 women undergoing TAH under a modified thoraco-lumbar double-space CSE with the "Spinal-First, Injection-Last" workflow demonstrated 100% procedural success, uniform rapid onset of a dense surgical block up to T6, 100% catheter integrity on removal, and low pain scores throughout the first 48 postoperative hours. To the best of our knowledge, this is the first formal description of a resequenced dual-space CSE that structurally—not merely probabilistically—removes the risk of catheter shearing.
Mechanical rationale
Catheter shearing during dual-space CSE is a rare but well-documented complication. In the conventional sequence, an epidural catheter placed at L2–L3 or L3–L4 may lie within the needle path of a subsequent spinal puncture at T12–L1 or higher, and a cephalad-directed catheter tip may be transfixed by the advancing spinal needle.¹⁹⁻²³ Even when the puncture sites appear distant on the skin, the catheter may drift laterally in the epidural fat and cross the trajectory of the spinal needle.³⁹ By reversing the sequence—placing the spinal needle first, keeping it stationary, threading the catheter afterwards, and injecting the intrathecal drug only after the catheter is safely fixed—we eliminate the possibility of a moving spinal needle encountering the catheter. The 4–5 cm cephalad thread of the L1–L3 catheter reaches, at most, T12–L1, well below the stationary T11–T12 spinal needle, keeping the catheter and needle bevel physically separated.
Choice of the low-thoracic interspace
Segmental thoracic spinal anaesthesia at T9–T11 has been shown by multiple investigators to be safe and effective for upper abdominal, laparoscopic and open lower abdominal surgery.²⁶⁻²⁸,⁴⁰ Imbelloni and colleagues demonstrated, in an anatomical MRI study, that the distance between the dura and the spinal cord at T10–T12 averages 5.8–7.5 mm, sufficient to accommodate a 25G needle safely.⁴¹ Van Zundert and colleagues reported segmental thoracic spinal anaesthesia in over 600 patients without any neurological complication.⁴² The reduced dose of hyperbaric bupivacaine (7.5–12.5 mg) required at thoracic levels also lowers the risk of profound hypotension seen with equivalent lumbar doses spreading cephalad.⁴⁵ In our series, 12.5 mg of hyperbaric bupivacaine with 25 μg fentanyl consistently produced a T6 peak block with Bromage 3 motor block in a median of 5 minutes—comparable to published data for segmental thoracic spinal anaesthesia and superior to equipotent lumbar spinal doses for onset and abdominal wall relaxation.⁴⁰,⁴³ We deliberately targeted a T6 sensory level rather than a higher T4 block, since coverage to T6 is sufficient for the T10–L1 uterine somatic afferents and T5–L2 sympathetic outflow relevant to TAH, while sparing the upper thoracic (T1–T4) cardio-accelerator fibres and diaphragmatic innervation, thereby minimising the risk of profound hypotension, bradycardia and subjective breathlessness seen with higher blocks.
Comparison with needle-through-needle CSE
The NTN CSE has become the default in many institutions because of its supposed simplicity.¹² However, several disadvantages persist: (i) the epidural catheter cannot be tested before spinal injection, so an intravascular or intrathecal catheter is only unmasked after fixed spinal anaesthesia is established;¹⁴ (ii) the long spinal needle can drag epidural tissue or metallic microparticles into the subarachnoid space;¹⁶ (iii) failed dural puncture despite correct epidural placement is reported in 5–16% of cases;¹⁷ and (iv) the epidural catheter, when subsequently threaded, may migrate through the dural rent, converting the spinal into unintended continuous spinal anaesthesia.¹⁵ Our dual-space resequenced approach avoids all four of these limitations. The epidural catheter is placed independently and can be aspirated and test-dosed with lignocaine-adrenaline before any spinal injection.³⁵ There is no coaxial passage of the spinal needle through the Tuohy bevel, and the risk of dural translocation of the catheter is negligible when the catheter sits at L1–L3 and the spinal puncture is at T11–T12.
Comparison with conventional dual-space CSE
The conventional dual-space sequence has the well-known through-and-through hazard already discussed. Additionally, when the epidural is placed first and dosed with a test bolus, the resulting incipient neuraxial block may make patient positioning and subsequent dural puncture at a higher interspace difficult or uncomfortable. Reversing the order, as we have done, avoids this by delaying any pharmacological effect until the technical work is complete.
Postoperative analgesia and functional recovery
The intact lumbar epidural catheter provided excellent postoperative analgesia, with a mean 24-hour VAS at rest of 2.1 and low rescue requirement. This is consistent with a substantial body of evidence supporting continuous thoracic and lumbar epidural analgesia in reducing pain scores, opioid consumption, pulmonary complications and length of stay after major abdominal surgery.³⁸,⁴⁴,⁴⁵ Early ambulation, achieved in the majority of our patients by the end of postoperative day 1, is an important element of enhanced recovery after surgery (ERAS) pathways for gynaecological surgery.⁴⁶
Safety profile
The complication profile in our series compares favourably with published CSE data. The 26.7% incidence of hypotension is comparable to the 20–40% reported for lumbar CSE with similar doses.⁴⁷ There were no cases of post-dural puncture headache; the use of a 25G Quincke needle and a single dural puncture likely contributed to this. Importantly, there were no cases of catheter shearing, transient neurological symptoms, or persistent neurological deficit.
Limitations
Our study has several limitations. First, it is an observational series without a randomised comparator arm; head-to-head trials against NTN CSE and conventional dual-space CSE are needed to confirm superiority. Second, the sample size of 45 is modest and precludes precise estimation of the incidence of very rare complications such as catheter shearing or permanent neurological injury. Third, the technique requires proficiency in thoracic neuraxial access and may not be immediately transferable to trainees or low-volume settings without appropriate training. Fourth, the paramedian approach at T11–T12, while anatomically favourable, requires familiarity that may not be universal.⁴⁸,⁴⁹
Future directions
Randomised controlled trials comparing the "Spinal-First, Injection-Last" thoraco-lumbar CSE with standard techniques for TAH and other lower abdominal surgeries are warranted. Pre-procedural ultrasound guidance may further increase the safety and reproducibility of the thoracic puncture, particularly in patients with challenging anatomy.⁵⁰.
The "Spinal-First, Injection-Last" thoraco-lumbar double-space CSE technique is a simple, anatomically precise resequencing of the standard dual-space approach that structurally eliminates the risk of epidural catheter shearing by the spinal needle. In our series of 45 women undergoing TAH, the technique delivered rapid, dense, T6-level surgical anaesthesia with 100% catheter integrity, stable intraoperative haemodynamics, and excellent postoperative analgesia via the intact lumbar epidural catheter. This modification preserves all the clinical advantages of CSE—rapid onset, dense block, prolonged analgesia—while removing one of its most feared, if uncommon, mechanical complications. It merits wider evaluation in prospective randomised trials.